• High Performance Digital Weight Indicator For Crane Overload Protection
  • High Performance Digital Weight Indicator For Crane Overload Protection
  • High Performance Digital Weight Indicator For Crane Overload Protection
  • High Performance Digital Weight Indicator For Crane Overload Protection
  • High Performance Digital Weight Indicator For Crane Overload Protection
High Performance Digital Weight Indicator For Crane Overload Protection

High Performance Digital Weight Indicator For Crane Overload Protection

Product Details:

Place of Origin: China
Brand Name: Supmeter
Certification: CE
Model Number: BST106-B60S(C)

Payment & Shipping Terms:

Minimum Order Quantity: 1pcs
Price: Negotiation
Packaging Details: 1pcs/box
Delivery Time: 1-20 working days
Payment Terms: T/T, Western Union
Supply Ability: 1000pcs/month
Get Best Price Contact Now

Detail Information

Power Supply: DC24V DO: 2
AO: 1 COM1: RS232
COM2: RS485
High Light:

digital weighing indicator

,

digital display system and indicators

Product Description

Mini Crane Overload Protection Digital Weight Indicator For Crane Overload Protection

 

 

      Main Features:

  • Suitable for Crane [Wheel Crane, Travelling Crane, Frame Crane, Bridge Crane and so on] Overload Protection. When the lifting weight exceeds the set values, the controller will output the signal of Sound-light Pre-alarm for Weight High Limit, Delay-stop for Weight Higher Limit and Emergency-stop for Weight Highest Limit to protect the crane.
  • EMC design with high anti-jamming capability, suitable for industrial environment.
  • 32-bit ARM CPU with 48MHz clock & higher arithmetic speed.
  • 5 Red LED digital tubes for English character and digit display.
  • Menu&Shortcut mode operation.
  • 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 640Hz.
  • Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
  • Optional weighing input signal mV, V and mA for connecting ‘【mV】Output Type Loadcell’, ‘【V】Voltage Output Type Weighing Transmitter’ and ‘【mA】Current Output Type Weighing Transmitter’.
  • Auto Zero Initial Calibration after Power-on, Auto Zero Tracking, Zero Fine Adjustment, Zero Calibration and Load Calibration functions available.
  • Optional Data Calibration function.
  • Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing functions available.
  • 2 Relay switches with normally open and normally closed contacts for outputting alarm signals.
  • 1 Optional and definable analog signal output [AO: 0~20mA].
  • Optional RS232 and RS485 communication ports for connecting Host IPC/PLC and LED Remote Display.
  • With the multitasking mode, the processes of weighing, alarm output and signal transmission will not be interrupted by parameter setting and the other operations.

 

      Picture

 

High Performance Digital Weight Indicator For Crane Overload Protection 0

High Performance Digital Weight Indicator For Crane Overload Protection 1

High Performance Digital Weight Indicator For Crane Overload Protection 2

     Keypad Operation

If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.

 

Menu Operation
Key Name Description
【■】 Enter Main Menu / Exit.
8 Enter / Save / Alarm Acknowledge.
【►】

Cursor shifts right.

Display the previous option.

【▲】

Display the next interface or option.

Digit input: +1 ( 0~9 loop).

 

 

Quick Operation
Key Name Description
【■】*

* Keep the key pressed for 2 seconds:

  • Key-locking.
  • Key-unlocking.

【►】

(【SET】)

Setpoint parameters setting.

【▲】

(【→0←】)

(【ZERO】)

  • [≡ZEro]: Zero Fine Adjustment without Power-down Protection. If the LED light [NZ] turns on, the operation will be invalid.
  • [-ZEro]: Zero Calibration with Power-down Protection.

 

           State Indication

LED light Description Note
[AL] ON: Sound-light Pre-alarm Setpoint for Weight High Limit. Refer to Parameters [200]~[203].
[AH]

Slow Blinking: Delay-stop for Weight Higher Limit.

Fast Blinking: Emergency-stop for Weight Highest Limit.

[NZ] ON: The opearion ‘Zero Fine Adjusting Range’ is unallowed. Refer to Parameter [204].

         

 

 

 

           Alarm Sign

Sign Alarm Cause Solution
Err0 Weighing Signal Type Error. Power-on again after making sure that the set value of parameter [111] ‘Weighing Signal Type’ and the switch position of DIP1/DIP2 are matched with the actual weighing input signal.
Err1 RAM Failure. Replace the chip RAM.
Err2.1/Err2.2 EEPROM Failure. Replace the chip EEPROM.
Err3 Unused.  
Err4 ADC Failure. Replace the ADC module.
oV-Ad Over ADC Range.

Weighing signal exceeds A/D conversion range.

1. Check if the loadcell is connected.

2. Check if the capacity of loadcell is too small.

3. Check if the loading weight is too big.

oL Overload Alarm.

Weight > (Scale Capacity + 9 × Scale Division).

1. Check if the loadcell is connected.

2. Check if the capacity of loadcell is too small.

3. Check if the loading weight is too big.

oV-nZ Over ‘Zero Fine Adjusting Range’. Refer to parameter [123] ‘Zero Fine Adjusting Range’.
tXX.XX Preheating Time Countdown [min.sec].

Refer to parameter [128] ‘Initial Zero Adjustment after Power-on’, [129] ‘Initial Zero Adjusting Time’ and [130] ‘Initial Zero Adjusting Range’.

Wait for the preheating time over or press any key to exit.

oV-Zr Over ‘Initial Zero Adjusting Range’.

 