VFD Panel Mounting Material Level Weighing Controller For Hopper Scale And Platform Scale
Product Details:
Place of Origin: | China |
Brand Name: | Supmeter |
Certification: | CE |
Model Number: | BST106-C11 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1PCS |
---|---|
Packaging Details: | 1pcs/box |
Delivery Time: | 1-20 working days |
Payment Terms: | Western Union, T/T |
Supply Ability: | 500PCS per month |
Detail Information |
|||
Power Supplier: | DV24v | Loadcell: | 8 Loadcell Connectable(350ohm) |
---|---|---|---|
DI: | 3 | DO: | 4 |
Communication: | RS232/RS485 | ||
High Light: | electronic weight indicator,digital load controller |
Product Description
VFD Panel-mounting Material Level Weighing Controller For Hopper Scale And Platform Scale
Technical Specifications
- Power Supply: AC220V±15%, 50/60Hz, Max. 10W.
- Loadcell Excitation Voltage/Current: DC10V/250mA.
- 8 Loadcells[350Ω] connectable.
- Weighing Signal Input Range: 0~25mV.
- 3 Normally Open Switch Inputs [DI].
- 4 Normally Open Relay Outputs [DO]: AC250V/DC24V, 1A.
- 1 Analog Signal Output [AO]: 4~20mA, 0.05%FS.
- COM1: Fixed RS232&RS485. Free to use one of them.
- COM2: Optional RS232/RS485/RS422/Profibus-DP/Ethernet.
- Connect Host IPC, Remote Display, Printer&Wireless Module.
- Outline Size [W×H×D]: 160 × 84 × 188 mm.
- Panel Cut-out Size [W×H]: 151 × 76 mm.
- Operating Temperature: -25℃~+45℃.
- Protection Level of Front Panel: IP65.
- Accuracy Grade: III.
- Verification Accuracy: 0.02%.
- Static Weighing Accuracy: 0.2%~0.5%.
Model Panel-mounting Installation
Model |
Outline Size W×H×D [mm] |
Front Panel Size W1×H1 [mm] |
Box Body Size W×H [mm] |
Panel Cut-out Size W×H [mm] |
DC24V | 170×91×184 | 170×91 | 150×75 | 151×76 |
AC220V | 160×84×188 | 160×84 | 150×75 | 151×76 |
Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 【ESC】 (【LOCK】) |
Enter Main Menu. Exit. Keep it pressed for 2 seconds: Key-locking / Key-unlocking. |
【ENT】 | Enter/Save/Clear Alarm. |
【◄】 | Cursor shifts left. |
【►】 | Cursor shifts right. |
【▲】 |
Display the previous option. Digit input: +1. |
【▼】 |
Display the next option. Digit input: -1. |
Quick Operation | |
【G/N】 | APL0 Hopper Weighing Mode: Gross Weight / Net Weight display switch. |
APL1 Ration Batching Mode: Gross Weight / Net Weight / Feeding Weight display Switch.
|
|
【ZERO】 |
|
【TARE】 |
|
【CAL】 |
|
【▲】【▼】* | * Keep it pressed for 2 seconds: Setpoint parameters setting. |
【PRINT】 | Print Weighing/Batching Report. |
Hopper Weighing Mode :
Material M1 Ration Feeding Mode
Material M1~M3 Ration Batching Mode