Electronic Wheel Loader Scales, Loader Weighing Scales With Stainless Steel Shell
Product Details:
| Place of Origin: | China | 
| Brand Name: | Supmeter | 
| Certification: | CE | 
| Model Number: | BST106-N59(B) | 
Payment & Shipping Terms:
| Minimum Order Quantity: | 1pcs | 
|---|---|
| Price: | Negotiation | 
| Packaging Details: | 1pcs/box | 
| Delivery Time: | 3-20 days | 
| Payment Terms: | T/T, Western Union | 
| Supply Ability: | 300pcs per month | 
| 
                             Detail Information  | 
                    |||
| Power Supply: | DC24V Or DC12V | Oil Pressure Sensor: | 0~40mA | 
|---|---|---|---|
| Accuracy Of Single Bucket: | 0.5%~1.0% | Accuracy Grade: | III | 
| Loading Record: | Max. Save 1000pieces | Sampling Frequncy: | 400Hz | 
| Highlight: | electronic weight indicator,china weighing indicator | 
                                                    ||
Product Description
Electronic Wheel Loader Scales, Loader Weighing Scales With Stainless Steel Shell
 
      Main Features:
- EMC design with high anti-jamming capability, suitable for industrial environment.
 - DC24V power input circuit with reverse polarity protection function.
 - 32-bit ARM CPU with 72MHz & higher arithmetic speed.
 - Dust-proof stainless steel shell with protection level IP65.
 - 640×480 TFT color display screen for English character display.
 - The display informations of Bucket Lifting/Declining state, Single-bucket-loading-weight, Totalized Loading Weight, Positive/Negative Deviation Value, Alarm state, Date/Time and other auxiliary data are used for judging if Single-bucket-loading-weight is valid and the loading process should be stopped.
 - 20-key English keypad with controllable backlight.
 - Number and English Alphabet can be inputted.
 - The informations of User Name, Truck No., Goods No. and Operator No. can be inputted.
 - Upper/Lower Limit of Single-bucket-loading-weight, Setpoint of Totalized Loading Weight and Date/Time can be set.
 - Operating Time, Single-bucket-loading-weight, Totalized Loading Weight and Alarm Information can be recorded automatically.
 - Using two oil pressure sensors for higher weighing accuracy than using one.
 - 24-bit ∑-△ADC with internal resolution 1/1,000,000 and sampling frequency 400Hz.
 - High sampling frequency, anti-vibration digital filter and acceleration compensation algorithm for ensuring high weighing accuracy in the lifting process of the bucket.
 - 10000 Loading Records can be saved, queried and printed, and each record can contain 50 Single-bucket-loading-weight value.
 
Picture
![]()
![]()
![]()
     Structure of Wheel loader
![]()
 
Related Operation Terms:
- Arm-up: Lift the lift-arm so that the bucket rises.
 - Arm-down: Put the lift-arm down so that the bucket goes down to the lowest position.
 - Bucket-up: Flip the bucket upward to the limit position.
 - Bucket-down: Flip the bucket downward.
 - Discharge: Flip the bucket downward for discharging materials.
 
Main Menu
| Main Menu | Second Menu | Description | 
| 
			 F1: SET  | 
			1 Weighing | Weighing parameters setting. | 
| 2 Calibration | Calibration parameters setting. | |
| 3 Setpoint | Setpoint parameters setting. | |
| 4 Alarm | Alarm parameters setting. | |
| 5 Communcation | Communication parameters setting. | |
| 6 Display | Display and operation interface parameters setting. | |
| 7 Time | 
			 Time parameter setting. 
  | 
		|
| 
			 F2: CAL  | 
			1 Zero Cal. [Unload&Idle] | 
			 Zero Calibration.  | 
		
| 2 Zero Comp. [Unload&ACC] | 
			 Zero Compensation.  | 
		|
| 3 Span Cal. [Load&Idle] | 
			 Span Calibration.  | 
		|
| 4 Span Comp. [Load&ACC] | 
			 Span Compensation.  | 
		|
| 
			 F3: REC  | 
			1 Query Truck Records | Query Truck Loading Records. | 
| 2 Query Mixing Records | Query Mixing Records. | |
| 3 Query Shift Records | Query Shift Records. | |
| 4 Clear Truck Records | Clear Truck Loading Records. | |
| 5 Clear Mixing Records | Clear Mixing Records. | |
| 6 Clear Shift Records | Clear Shift Records. | |
| 7 USB-Copy Truck Records | Copy Loading Records without Single-bucket-loading -weight to U-disk. | |
| 8 USB-Copy Detail Records | Copy Loading Records with Single-bucket-loading-weight to U-disk. | |
| 9 USB-Copy Detail Records | Copy the Shift Records to U-disk. | 
| Main Menu | Second Menu | Description | 
| 
			 F4: LOC  | 
			1 Key-unlocking | Unlocking keypad. | 
| 2 Key-locking | Locking keypad. | |
| 3 Password Set | 
			 Exfactory Passwords: 
  | 
		|
| 
			 F5: FAC  | 
			Special for manufacturer. | |
| 1 Hardware Test | AD Value of Oil Pressure Signal Linearity Test and Position Signal Test. | |
| 2 Simplified Chinese | Download Simplified Chinese. | |
| 3 Complex Chinese | Download Complex Chinese. | |
| 4 Parameter Backup | Parameter Backup. | |
| 5 Parameter Recovery | Parameter Recovery. | |
| 6 Reset Defaults | Reset to factory defaults. | |
| 
			 F6: INF  | 
			Only for query. | |
| 1 Version No. | 1 Version No. | |
| 2 Serial No. | 2 Serial No. | |
| 3 Exfactory Date | 3 Exfactory Date. | |