HMI Load Cell Display And Controller With 4 Material & 2 Speed Feeding
Product Details:
Place of Origin: | China |
Brand Name: | Supmeter |
Certification: | CE |
Model Number: | BST106-M10[FB] |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pcs |
---|---|
Price: | Negotiation |
Packaging Details: | 1pcs/box |
Delivery Time: | 3-10 working days |
Payment Terms: | T/T, Western Union |
Supply Ability: | 10000pcs per month |
Detail Information |
|||
Power Supply: | DC24V | Max. Connect: | 16Loadcells[350Ω] |
---|---|---|---|
Input: | 7DIs | Output: | 18DOs |
COM@COM1: | RS232 | COM2: | RS485 |
High Light: | programmable load cell controller,load cell display unit |
Product Description
HMI Load Cell Display And Controller With 4 Material & 2 Speed Feeding
HMI Weighing Controller For Ration Batching Scale with 4-material&2-speed Feeding
Main Features:
- EMC design with high anti-jam for industrial environment.
- DC24V power input with reverse polarity protection.
- Cortex-A8 CPU with 600MHz Clock, 128M Flash.
- 7” [800×480] or 10.2” [1024×600] TFT touch panel.
- 24-bit ∑-△ADC with internal resolution 1/1,000,000.
- High sampling frequency 800Hz.
- Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid response.
- Auto Zero Tracking.
- Fall Value Auto Correction.
- Auto Pause for Deviation Alarm.
- Auto Re-feed for Negative Deviation Alarm.
- Target Batch Count & Target Batch Weight Control.
- 3-speed[high/medium/low] feeding control by DOs or AOs.
- Definable DI/DO/AO/COM[Communication Port].
- Recipe Number: 100.
Technical Specification:
Power Supply | DC24V±20%,Max.10w. |
Display | HMI |
Sampling Frequency | 800Hz |
A/D Convert | 24-bit |
LAN | Optional Ethernet |
USB1 | Connect mouse, software download, data backup |
Max. Connection number of Loadcell |
16Loadcells (350Ω) |
DI | 7 Normally Open Switch Inputs |
DO | 18 Normally Open Transistor Switch Outputs |
AO | 4Analog Signal Output: 4~20mA. |
Operating Temperature | -25℃~+45℃ |
Verification Accuracy | 0.02% |
Batching Accuracy | 0.2%~0.5% |
Main Operation Interface for APP1 Single-scale Mode
Main Operation Interface for APP2 Four-scale Mode
Button Operation
Name | Operation | State Indicator | Authorization |
【Auto】 | Auto / Manual [Emergency Stop] switch. |
Green: Auto state. Grey: Manual state. |
All Users |
【Start】 | Start. |
Green: Running state. Grey: Stop state. |
|
【Re-run】 | Clear Alarm & Recover Running. | ||
【Last】 |
Last Batch [Normal Stop]. Stop after the present batch finished. |
Flashing Red. | |
【Pause】 | Pause. | ||
【E-stop】 | Emergency Stop. | ||
【Alarm】 |
Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after clearing alarm. |
Red: Alarm state. | |
【Mat.】 |
Material Selection for Auto-Batching. Mixer in Weighing Hopper Running Selection While High-speed Feeding [Only for Single-scale Mode]. |
Green/Blue: Selected. Grey: Unselected. |
|
【Print】 |
Report Print:
|
||
【Lock】 |
Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901]. |
Flashing Red: Locked. Grey: Unlocked. |
|
【Menu】 | Enter Main Menu. | ||
【User】 | User Login. Display: Operator / Engineer / Admin. | ||
【Zero】 | Zero Fine Adjustment [No Power-down Protection]. | Flashing green. | |
【High】 | Manual Start/Stop Mn High-speed Feeding. | Green: Working state. | |
【Low】 | Manual Start/Stop Mn Low-speed Feeding. | ||
【Dump】 | Manual Start/Stop Dumping. | ||
【MixbinDump】 | Manual Start/Stop Mixing Bin’s Dumping. | ||
【Mn】 | Material Selection for Manual Operation. | ||
【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized Weight and Batch Count’. |
Engineer Administrator |
Data Display & Quick Setting
Name | Description | Authorization |
Biggest Digits | Real-time Weight / Material Mn’s Feeding Weight [Weight Unit]. | |
[GROSS] | Gross Weight. | |
[HI] | Gross Weight Upper Limit Alarm. | |
[OL] | Overload Alarm. | |
[CYCLES] | Batch Count. | |
[▲]/HI | Positive Deviation Alarm. | |
[▼]/LO | Negative Deviation Alarm. | |
[TOTAL] | Total Totalized Weight. | |
[RUN] | Auto Running state. | |
[PAUSE] | Pause state. | |
[ZERO] | Gross Weight ≤ Non-load Zero Range. | |
[STAB] | Weight is stable. | |
[FED] | Material Mn Feeding Ended. | |
[AU_FALL] | ‘Fall Value Auto Correction’ Permission. | |
[ALL_FED] | All Materials Feeding Ended. | |
[BAT_CON] | ‘Target Batch Control’ is allowed. Refer to parameter [301] ‘ Target Batch Control’ and [203] ‘ Target Batch’. | |
[BAT_FIN] | Target Batch Finished. | |
[MIX]/[MIXING] | The mixer is running. | |
[BELT] | The mixing conveyor is running. | |
[RECIPE] | ‘Working Recipe’ Setting. | All Users |
[Mn TARGET] | Mn Target Value. | |
[Mn FINAL] | Mn Final Feeding Weight. | |
[SUM TARGET] | The sum of the Target Values of all the materials selected for batching. | |
[SUM FINAL] | The sum of the Final Feeding Weight of all the materials selected for batching. | |
[CYCLES TARGET ] [BAT. COUNT] |
Target Batch Count. | |
[CYCLES FINAL] | Batch Count. | |
[Time] | Date&Time. |
HMI TFT-Touch Raiton Filling Controller For Filling Liquid, Gas & Powder Materials
Outline Size
Installation Mode
Terminal Diagram
System Diagram: