HMI Load Cell Display And Controller With 4 Material & 2 Speed Feeding
Product Details:
| Place of Origin: | China |
| Brand Name: | Supmeter |
| Certification: | CE |
| Model Number: | BST106-M10[FB] |
Payment & Shipping Terms:
| Minimum Order Quantity: | 1pcs |
|---|---|
| Price: | Negotiation |
| Packaging Details: | 1pcs/box |
| Delivery Time: | 3-10 working days |
| Payment Terms: | T/T, Western Union |
| Supply Ability: | 10000pcs per month |
|
Detail Information |
|||
| Power Supply: | DC24V | Max. Connect: | 16Loadcells[350Ω] |
|---|---|---|---|
| Input: | 7DIs | Output: | 18DOs |
| COM@COM1: | RS232 | COM2: | RS485 |
| Highlight: | programmable load cell controller,load cell display unit |
||
Product Description
HMI Weighing Controller For Ration Batching Scale with 4-material&2-speed Feeding
Main Features:
- EMC design with high anti-jam for industrial environment.
- DC24V power input with reverse polarity protection.
- Cortex-A8 CPU with 600MHz Clock, 128M Flash.
- 7” [800×480] or 10.2” [1024×600] TFT touch panel.
- 24-bit ∑-△ADC with internal resolution 1/1,000,000.
- High sampling frequency 800Hz.
- Special Anti-vibration Digital Filtering Algorithm for precise weighing, stable display and rapid response.
- Auto Zero Tracking.
- Fall Value Auto Correction.
- Auto Pause for Deviation Alarm.
- Auto Re-feed for Negative Deviation Alarm.
- Target Batch Count & Target Batch Weight Control.
- 3-speed[high/medium/low] feeding control by DOs or AOs.
- Definable DI/DO/AO/COM[Communication Port].
- Recipe Number: 100.
Technical Specification:
| Power Supply | DC24V±20%,Max.10w. |
| Display | HMI |
| Sampling Frequency | 800Hz |
| A/D Convert | 24-bit |
| LAN | Optional Ethernet |
| USB1 | Connect mouse, software download, data backup |
| Max. Connection number of Loadcell |
16Loadcells (350Ω) |
| DI | 7 Normally Open Switch Inputs |
| DO | 18 Normally Open Transistor Switch Outputs |
| AO | 4Analog Signal Output: 4~20mA. |
| Operating Temperature | -25℃~+45℃ |
| Verification Accuracy | 0.02% |
| Batching Accuracy | 0.2%~0.5% |
Main Operation Interface for APP1 Single-scale Mode
![]()
![]()
Main Operation Interface for APP2 Four-scale Mode
![]()
![]()
Button Operation
| Name | Operation | State Indicator | Authorization |
| 【Auto】 | Auto / Manual [Emergency Stop] switch. |
Green: Auto state. Grey: Manual state. |
All Users |
| 【Start】 | Start. |
Green: Running state. Grey: Stop state. |
|
| 【Re-run】 | Clear Alarm & Recover Running. | ||
| 【Last】 |
Last Batch [Normal Stop]. Stop after the present batch finished. |
Flashing Red. | |
| 【Pause】 | Pause. | ||
| 【E-stop】 | Emergency Stop. | ||
| 【Alarm】 |
Alarm Query / Clear Alarm. ‘Auto/Pause’ state: Recover Running after clearing alarm. |
Red: Alarm state. | |
| 【Mat.】 |
Material Selection for Auto-Batching. Mixer in Weighing Hopper Running Selection While High-speed Feeding [Only for Single-scale Mode]. |
Green/Blue: Selected. Grey: Unselected. |
|
| 【Print】 |
Report Print:
|
||
| 【Lock】 |
Screen-locking: Locking/unlocking the operating buttons of main display interface. Auto Screen-locking: Refer to parameter [901]. |
Flashing Red: Locked. Grey: Unlocked. |
|
| 【Menu】 | Enter Main Menu. | ||
| 【User】 | User Login. Display: Operator / Engineer / Admin. | ||
| 【Zero】 | Zero Fine Adjustment [No Power-down Protection]. | Flashing green. | |
| 【High】 | Manual Start/Stop Mn High-speed Feeding. | Green: Working state. | |
| 【Low】 | Manual Start/Stop Mn Low-speed Feeding. | ||
| 【Dump】 | Manual Start/Stop Dumping. | ||
| 【MixbinDump】 | Manual Start/Stop Mixing Bin’s Dumping. | ||
| 【Mn】 | Material Selection for Manual Operation. | ||
| 【Clear】 | Clear Screen: Clear the display values of Feeding Weight, Totalized Weight and Batch Count’. |
Engineer Administrator |
Data Display & Quick Setting
| Name | Description | Authorization |
| Biggest Digits | Real-time Weight / Material Mn’s Feeding Weight [Weight Unit]. | |
| [GROSS] | Gross Weight. | |
| [HI] | Gross Weight Upper Limit Alarm. | |
| [OL] | Overload Alarm. | |
| [CYCLES] | Batch Count. | |
| [▲]/HI | Positive Deviation Alarm. | |
| [▼]/LO | Negative Deviation Alarm. | |
| [TOTAL] | Total Totalized Weight. | |
| [RUN] | Auto Running state. | |
| [PAUSE] | Pause state. | |
| [ZERO] | Gross Weight ≤ Non-load Zero Range. | |
| [STAB] | Weight is stable. | |
| [FED] | Material Mn Feeding Ended. | |
| [AU_FALL] | ‘Fall Value Auto Correction’ Permission. | |
| [ALL_FED] | All Materials Feeding Ended. | |
| [BAT_CON] | ‘Target Batch Control’ is allowed. Refer to parameter [301] ‘ Target Batch Control’ and [203] ‘ Target Batch’. | |
| [BAT_FIN] | Target Batch Finished. | |
| [MIX]/[MIXING] | The mixer is running. | |
| [BELT] | The mixing conveyor is running. | |
| [RECIPE] | ‘Working Recipe’ Setting. | All Users |
| [Mn TARGET] | Mn Target Value. | |
| [Mn FINAL] | Mn Final Feeding Weight. | |
| [SUM TARGET] | The sum of the Target Values of all the materials selected for batching. | |
| [SUM FINAL] | The sum of the Final Feeding Weight of all the materials selected for batching. | |
|
[CYCLES TARGET ] [BAT. COUNT] |
Target Batch Count. | |
| [CYCLES FINAL] | Batch Count. | |
| [Time] | Date&Time. | |
HMI TFT-Touch Raiton Filling Controller For Filling Liquid, Gas & Powder Materials
![]()
Outline Size
![]()
Installation Mode
![]()
Terminal Diagram
![]()
System Diagram:
![]()