Analog Output Load Cell Display And Controller with LED Display
Product Details:
Place of Origin: | China |
Brand Name: | Supmeter |
Certification: | CE |
Model Number: | BST106-B60S(L) |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pcs |
---|---|
Packaging Details: | 1pcs/box |
Delivery Time: | 3-20 working days |
Payment Terms: | T/T, Western Union |
Supply Ability: | 1000pcs per month |
Detail Information |
|||
Power Supplier: | DC24V | Loadcell: | 8 Loadcell Connectable 350ohm |
---|---|---|---|
COM1: | RS232 | COM2: | RS485 |
Outline Size: | 107*60*100mm | ||
High Light: | Analog Load Cell Display And Controller,LED Load Cell Display And Controller,Analog Output load cell Controller |
Product Description
Analog Output Load Cell Display And Controller with LED Display
Analog Output Weighing Controller Indicator Load Cell Indicator LED Display
Main Application:
Weight/Force Display
Peak Value Detection/Display Holding
Setpoint DO Output
Weight/Force Signal AO/Digit Transmission
Weight/Force Increament/Decrement DO Output Mode
Weight/Force Section DO Output Mode.
Main Feature:
1:32-bit ARM CPU with 48MHz clock and high arithmetic speed.
2: Auto Zero Tracking
3: Load Calibration,Data Calibration&Segmenting Correction
4: Definable AO/COM[Communication Port]
Technical Specifiction:
Power Supply | AC24V±20% |
Display | 5 Red Led Digital Tubes for English&Digit Display |
Sampling Frequency | 1280Hz |
A/D Convert | 24-bit |
Keypad | 4 keys for Shortcut mode operation with key tone |
Excitation Voltage Output of Loadcell | DC5V |
Max. Connection number of Loadcell | 8 Loadcells (350Ω) |
[mV]Signal Input Range | 0-19.5mV |
DO | 2 Normally Open Transistor Switch Outputs |
AO | 1Analog Signal Output: 4~20mA. |
Communication Port | COM1:RS232;COM2:RS485 |
Outline Dimension | 107 × 60 × 100 mm (W×H×D) |
Net Weight | Approx. 1.2kg |
IP Grade | IP65 |
Verfication Accuracy | 0.03% |
Static Weighing/Force Measuring Accuracy | 0.2%~.5~ |
Model Panel-mounting Operation Interface
Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically
Menu Operation | |
Key Name | Description |
【MENU】 |
Enter Main Menu. Exit. |
【ENT】 | Enter / Save / Alarm Acknowledge. |
【◄】 |
Cursor shifts left. Display the previous option. |
【►】 |
Cursor shifts left. Display the next option. |
【▲】 |
Display the next interface or option. Digit input: +1 ( 0~9 loop). |
【▼】 |
Display the previous interface or option. Digit input: -1 ( 0~9 loop). |
Quick Operation | |
【MENU】 【Ñ】 * |
|
【◄】 (【SET】) |
Recipe parameters setting. |
【◄】 【ZERO】 【→0←】 * |
|
【▲】 【TARE】 【→T←】 * |
|
【ENT】 【G/N】 |
Gross Weight / Net Weight display switch. |