VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm
Product Details:
Place of Origin: | China |
Brand Name: | Supmeter |
Certification: | CE |
Model Number: | BST106-H18 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pcs |
---|---|
Price: | Negotiation |
Packaging Details: | 1pcs/box |
Delivery Time: | 3-10 working days |
Payment Terms: | T/T, Western Union |
Supply Ability: | 1000pcs/month |
Detail Information |
|||
Power Supply: | AC85-264V | DI: | 7 |
---|---|---|---|
DO: | 12 | COM1: | RS232 |
COM2: | Optional RS2332/RS485/Ethernet | ||
High Light: | digital load cell indicator,digital display system and indicators |
Product Description
VFD Ration Batching Controller Digtal Weight Indicator For 5-Material Ration Batching Scale
Main Features:
- Suitable for Ration Batching Scale with 5-Material&2-Speed Feeding [Single-Scale Mode].
- EMC design with high anti-jamming capability, suitable for industrial environment.
- 32-bit ARM CPU with 72MHz clock & higher arithmetic speed.
- 6+10 green VFD digital tubes for English character and digit display.
- 8-key English keypad.
- Menu&Shortcut mode operation with key tone.
- 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 400Hz.
- Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
- Max. Connection Quantity: 8 Loadcells (350Ω).
- Auto Zero Initial Calibration after Power-on, Auto Zero Tracking, Zero Fine Adjustment, Zero Calibration and Load Calibration functions available.
- Optional Data Calibration function.
- Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing functions available.
- 7 Normally open switch inputs [DI] and 12 normally open transistor switch outputs [DO].
- Optional ‘High/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
- 1 Optional and definable analog signal AO[4~20mA] for weight signal output or ‘High/Low Speed Feed’ control.Optional ‘Fall Value Auto Correction’ function.
- 10 Recipes for batching control.
- Optional ‘Fall Value Auto Correction’ function.
- Optional ‘Auto Pause for Deviation Alarm’, ‘Auto Pause for Gross Weight Upper Limit Alarm’ and ‘Manual Pause’ functions.
- Optional ‘Target Batch Control’ function [With Target Batch Count finished, the batching process will stop automatically].
- ‘Batching Process Power-off Protection’ function available.
- 2 Optional communication ports for connecting Host IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
- The present Batch Record can be printed automatically and manually.
- 500 Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
- With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.
Pictures
Technical Specification
- Executing Standard
- CMC GB/T 7724-2008PRC National Standard.
- OMIL R76: 2006International Recommendation.
- Accuracy Grade: III.
- Verification Accuracy: 0.02%.
- Static Weighing Accuracy: 0.2%~0.5%.
- Batching Accuracy: 0.2%~0.5%.
- Display
- 6+10 Green VFD digital tubes for English character and digit display.
- Weight Display Range: -99,999~+999,999.
- Scale Capacity: Setting Range 1~999,999.
- Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
- Display Resolution: 1/100,000.
- Weight Unit: Optional kg, t, g, none.
- Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
- Display Refreshing Time: Setting Range 0.01~1.00s.
- Kaypad
- 8-key English keypad.
- Menu&Shortcut mode operation with key tone.
- Loadcell Interface
- Excitation Voltage/Max. Current: DC10V/250mA [8-350Ω loadcells].
- Signal Input Range: 0~25mV.
- Output Sensitivity of Loadcell: 1.0~2.5mV/V.
- 24-bit ∑-△ADC with internal resolution 1/1,000,000.
- Sampling Frequency: 400Hz.
- Special anti-vibration digital filtering algorithm.
- Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
- Gain Drift: ±5ppm/℃.
- Non-linearity: 0.005%FS.
- Switch&Analog Signal Interface
- 7 Normally Open Switch Inputs [DI].
- 12 Normally Open Transistor Switch Outputs [DO]: DC24V, 500mA.
- 1 Optional&Definable Analog Signal Output [AO]: 4~20mA, Non-linearity: 0.05%FS.
- Digital Communication Interface
- COM1: RS232.
- COM2 Optional: RS232/RS485/RS422/Profibus-DP/Ethernet modules.
- Connectable: Host IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
- Report Print
- The present Batch Record can be printed automatically and manually.
- 500 Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
- Operating Specification
- Optional Operating Voltage
- Operating Voltage 1: DC24V±20%.
- Operating Voltage 2: AC85~264V, 50/60Hz.
- Operating Voltage 3: AC220V±15%, 50/60Hz.
- Free to configure one of them.
- Max. Power Consumption: 10W.
- Outline Size
- Model Panel-mounting: 164×82×188mm [W×H×D].
- Model Explosion-proof: 340×390×205mm [W×H×D].
- Panel Cut-out Size
- Model Panel-mounting: 153×77mm [W×H].
- Operating Temperature: -25℃ to +45℃.
- Storage Temperature: -30℃ to +60℃.
- Relative Humidity: Max. 85%RH.
- Application Environment of Model Explosion-proof
- Explosion gas environment: Zone 1&2.
- Classes of explosion gas mixture: IIA, IIB.
- Temperature grades of explosion gas mixture: T1~T6.
- Ex-mark: Ex d IIB T6 Gb.
- Protection Level
- Front Panel of Model Panel-mounting: IP65.
- Model Explosion-proof: IP65.
- Weight
- Model Panel-mounting: Approx. 1.6kg.
- Model Explosion-proof: Approx. 19.2kg.
Model Panel-mounting Operation Interface
Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 | Enter Main Menu / Exit. |
【ENT】 | Enter / Save / Alarm Acknowledge. |
【◄】 | Cursor shifts left. |
【►】 | Cursor shifts right. |
【▲】 |
Display the previous interface or option. Digit input: +1. |
【▼】 |
Display the next interface or option. Digit input: -1. |
Quick Operation | |
【Ñ】 * |
|
【SET】 | M1~M5 Target Values setting. |
【G/N】 | Gross Weight / Net Weight display switch. |
【→C←】 【CAL】 * |
Load Calibration. |
【→0←】 【ZERO】 * |
|
【→T←】 【TARE】 * |
|
【,】* | Record Query. |
【/】* | Clear Screen: Clear the display value of Tatal Feeding Weight, Totalized Weight and Batch Count. |
【‡】* | Time display and setting. |
【±】 | ‘+’/‘-’ switch. |
【6】 |
Main Display Interface:
Record Query state: Print Historical Batch Record. |
【ENT】 |
Pause State:
|
*: Keep the key pressed for 2 seconds.
State Indication
Sign | Description |
[GROSS] | Gross Weight display. |
[NET] | Net Weight display. |
[LOCK] |
ON: Key-locked. OFF: Key-unlocked. |
[◣◢] | Weight is stable: Weight Variance per [107] ‘Stablity Judging Time’ is in [106] ‘Stablity Judging Range’. |
[→0←] | The present Gross Weight or Net Weight display value is in ‘Display Value Auto-Zero Range’. |
[kg/t/g] | Weight unit. |
[ NUM] | Material No. display. |
[ PCS] | Batch Count display. |
[TOT] |
Totalized Weight display. Total Feeding Weight display. |
[SET] |
Target Value display. Parameter setting state. |
[RUN] |
ON: Running state. Blinking: Pause state. OFF: Stop or Calibrating state. |
[ZERO] | Net Weight ≤ Non-load Zero Range. |
[NZ] | It’s allowed to do Zero Fine Adjustment. |
[SP1] | High-speed Feeding. |
[SP3] | Low-speed Feeding. |
[FILL] | Stop state: Weight value is increasing. |
Running state: It’s in the feeding process. | |
[COMP] |
ON: It’s doing comparation between Feeding Weight and Target Value. OFF: It turns off in Comparing-prohibited Time. |
[DEV] | Positive/Negative Deviation Alarm. |
[FALL] | ON: Fall Value Auto Correction function is open. |
[DISC] | Stop state: Weight value is reducing. |
Running state: It’s in the dumping process. | |
[HH] | Gross Weight Upper Limit Alarm. |
Model Panel-mounting Installation
Model AC85~264V/AC220V Terminal
System Diagram for M1~M5 Ration Batching System