CE Approved Weigh Feeder Controller Vertical Panel Mounting Operation Interface supplier CE Approved Weigh Feeder Controller Vertical Panel Mounting Operation Interface supplier CE Approved Weigh Feeder Controller Vertical Panel Mounting Operation Interface supplier CE Approved Weigh Feeder Controller Vertical Panel Mounting Operation Interface supplier

Large Image :  CE Approved Weigh Feeder Controller Vertical Panel Mounting Operation Interface

Product Details:

Place of Origin: CHINA
Brand Name: SUPMETER
Certification: CE
Model Number: BST100-E01

Payment & Shipping Terms:

Minimum Order Quantity: 1 UNIT
Price: 400 USD PER UNIT
Packaging Details: Carton packing
Delivery Time: 3 WORKING DAY
Payment Terms: T/T
Supply Ability: 1000 UNIT PER MONTH
Contact Now
Detailed Product Description
Installation: Panel Mounted Display: LCD
Communication: RS232 A0: 4-20mA

WeighT Totalizing Loss In Weight Weighfeeder Controller With LED Display and RS232 Communication With AO 4-20mA                     

 

    Main Features:

  •  Suitable for Ration Belt Weighfeeder with Ration Flow Feeding & Ration Weight Batch Control.
  •  EMC design with high anti-jamming capability, suitable for industrial environment.
  •  32-bit ARM CPU with 72MHz & higher arithmetic speed.
  •  128×64 LCD display screen with 7 background colors for English display.
  •  16-key English keypad.
  •  Menu&Shortcut mode operation with key tone.
  •  High-precision ∑-△A/D conversion technology and broad-range speed pulse input circuit.
  •  Max. Connection Quantity: 8 Loadcells (350Ω).
  •  Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing
  • functions available.
  •  Auto Zero Tracking, Speed Calibration and Belt Length Calibration functions available.
  •  One optional ‘Flow Setpoint’ analog signal input [AI: 4~20mA].
  •  Max.3 definable ‘Flow/Control Current /…’ analog signal outputs [AO: 4~20mA].
  •  Quick and steady PID ration feeding control.
  •  3 Definable normally open switch inputs [DI] and 4 definable normally open relay switch
  • outputs [DO].
  •  The feeder and belt weigher can be started and stopped by DI&DO signal.
  •  1 ‘Totalized Weight High-speed Pulse’ output [PO].
  •  2 Optional communication ports for connecting IPC/PLC, LED Remote Display, Serial Printer
  • and Wireless Module.
  •  Weight Records per shift/day/month of a year can be queried and printed.
  •  With the multitasking mode, the weighing&control process will not be interrupted by parameter
  • setting and the other operations.

   Technical Specifications

  •  Power Supply: AC220V±15%, 50/60Hz, Max. 15W.
  •  Loadcell Excitation Voltage/Current: DC10V/250mA.
  •  8 Loadcells[350Ω] connectable.
  •  Weighing Signal Input Range: 0~25mV.
  •  Speed Sensor Excitation Voltage/Current: DC12V/100mA.
  •  Speed Signal Input Range: 0.5~3000Hz.
  •  3 Normally Open Switch Inputs [DI].
  •  4 Normally Open Relay Outputs [DO]: AC250V/DC24V, 1A.
  •  1 ‘Totalized Weight’ Pulse Output [PO]: DC5~24V, 100mA.
  •  2 ‘PID Control’ Analog Output [AO]: 4~20mA, 0.05%FS.
  •  1 ‘Flow Set’ Analog Input [AI]: 4~20mA, 0.05%FS.
  •  COM1: Optional RS232/RS485/RS422/Profibus-DP/Ethernet.
  •  COM2: RS232.
  •  Connect Host IPC, Remote Display, Printer&Wireless Module.
  •  Outline Size [W×H×D]: 164 × 86 × 193 mm.

 

Main MENU

Main Menu Second Menu Description
F1 Setting 1 Scale[Basic] Basic scale parameters setting.
1+Scale[Extra] Extra scale parameters setting.
2 Control[Basic] Basic feeding control parameters setting.
2+Control[Extra] Extra feeding and batching control parameters setting.
3 Flow Flow parameters setting.
4 Speed Speed parameters setting.
5 Load Load parameters setting.
6 Save/Print Weight record parameters setting.
7 Comm. Port Communication port parameters setting.
8 I/O Input&output parameters setting.
9 Display User interface parameters setting.
10 Date/Time Date/Time parameters setting.
F2 Calibration 1 Zero Cal. Zero Calibration without loading for correcting Zero Value.
2 Span Cal. Dyn. Dynamic Span Calibration with loading measured materials or Poise Weights for correcting Span Coefficient.
3 Span Cal.Stat1 Static Span Calibration with a measured chain weight as a continuous and steady load on the running belt weigher for correcting Span Coefficient.
4 Span Cal.Stat2 Static Span Calibration with a measured Hanging Weight as a steady load on the running belt weigher for correcting Span Coefficient.
5 Span Cor. Seg. Segmenting Span Correction. After doing Dynamic or Static Span Calibration, further corrections for 3 [AD Value: 0~60000] linear segments are optional for correcting Correction Coefficient 1~3.
6 Speed Cal.

Speed Coefficient Calibration.

Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Speed Coefficient.

7 Length Cal.

Belt Length Calibration.

Keep the belt weigher running at a constant speed. After the running time of a revolution being measured with using a stopwatch, do this operation for correcting Belt Length.

 

 

Main Menu Second Menu Description
F3 Weight Record   Query and print Weight Records.
F4 Data Clearing 1 Clear Screen

Clear Totalized Weight and Totalized Weight Pulse Count.

But Totalized Weight of Current Shift will not be cleared, so this operation has no effect on recording of weight per shift.

2 Clear Weight

Clear Totalized Weight, Totalized Weight Pulse Count and Totalized Weight of Current Shift.

The cleared value of Totalized Weight of Current Shift will not be recorded.

3 Clear Records

Clear History Records of Totalized Weight.

But Current Totalized Weight, Totalized Weight Pulse Count and Totalized Weight of Current Shift will not be cleared.

F5 Security 1 Auto-locking If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 Calibration’ & ‘F6 Factory Adj.’, the controller will lock the keypad and return to ‘Main Display Interface’ automatically.
2 Key-locking Locking keypad.
3 Key-unlocking Unlocking keypad.
4 Password Set Exfactory Password: 000001.
5 RAM Reset Restore to factory defaults.
F6 Factory Adj.   Special for manufacturer.
F7 Product Info. Only for query.
1 Version No. Version No.
2 Serial No. Serial No.
3 Exfactory Date Exfactory Date.
4 Audit Counter Audit Trail Counter [0~99999999] for Scale parameter’s modification.
5 Auth. Code Authorization Code.
 

 

Installation

CE Approved Weigh Feeder Controller Vertical Panel Mounting Operation Interface

FAQ:

1. Sample is Available?

Yes. This product support free sample. As long as you can bear the freight charge.

 

2. What detailed information do I need to provide if I want to place an order?

We need to know the following information: accuracy, Quantity, special requirements if you have, etc.

 

3. Do you have any discount?

Yes, if you buy large QTY, please send us a email, we will give you a big discount.

 

4. What terms of payment are available?

We accept T/T, L/C, Trade assurance, Secure payment, Western Union,etc.

 

5.When will you arrange the production?

We will arrange the production immediately after receiving your payment.

 

6. How do you ensure good product quality?

We have a complete quality control system, all of our products are fully checked by IQC, OQC departments before shipping to our clients.

 

7. How long is the warranty period?

The warranty period for our products is 12 (twelve) months.

If the products from SUPMETER are proved to be unable to work normally due to unartificial reasons, and the problems can't be solved by customers under the technical support from SUPMETER, then customers can send the problematic items back to SUPMETER. SUPMETER is RESPONSIBLE to MEND (or REPLACE when necessary) them FREE OF CHARGE.

(Note: if after checking, the returned goods are proved to be in good condition, the trouble is resulted to be caused by improper operation by customers, SUPMETER is IRRESPONSIBLE to bear the shipping & other charges related to the returning.)

Contact Details
CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID

Contact Person: He

Send your inquiry directly to us (0 / 3000)