Level Weighing Digital Scale Indicator VFD Display Material With RS485 And RS232
Product Details:
Place of Origin: | China |
Brand Name: | Supmeter |
Certification: | CE |
Model Number: | BST106-B11 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pc |
---|---|
Price: | negotiation |
Packaging Details: | carton |
Delivery Time: | 3workdays |
Payment Terms: | Western Union, T/T |
Supply Ability: | 6000pcs/month |
Detail Information |
|||
Power Supply: | DC24V | Material: | Steel |
---|---|---|---|
Static Weighing Accuracy: | 0.2%∼0.5% | Verification Accuracy: | III |
Output: | 4 Normally Open Transistor Switch Outputs | Input: | 3 Normally Open Switch Inputs |
High Light: | totalizer meter,digital indicator with remote display |
Product Description
VFD Display Material Level Weighing Digital Scale Indicator With RS485 And RS232
Main Application:
Material Level Scale, Hopper Scale&Platform Scale
Weight Limit DO Alarm Mode
Weight Increment/Decrement DO Output Mode
Main Features:
1: Auto Zero Tracking
2: Load Calibration&Data Calibration
3: The Weighing Record can be printed
4: Definable AO/COM[Communication Port]
Technical Specifications:
Power Supply | AC220v |
Display | 6 VFD Digital Tubes for English and Digit Display |
Sampling Frequency | 200Hz |
A/D Convert | 24-bit |
Keypad | 6 keys for Menu&Shortcut mode operation with key tone |
Excitation Voltage Output of Loadcell | DC10V |
Max. Connection number of Loadcell | 8 Loadcells (350Ω) |
DI | 3 Normally Open Switch Inputs |
DO | 4 Normally Open Transistor Switch Outputs |
AO | 1 Optional and Definable Analog Signal Output: 4~20mA. |
Communication Port |
COM1:Fixed RS232&RS485,Free to use one of them; |
Outline Dimension | 170× 91 × 184 mm (W×H×D) |
Net Weight | Approx. 2kg |
IP Grade | IP65 |
Verification Accuracy | 0.02% |
Static Weighing Accuracy | 0.2%-0.5% |
Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 |
Enter Main Menu. Exit. Keep it pressed for 2 seconds: Key-locking / Key-unlocking. |
【ENT】 | Enter/Save/Alarm Acknowledge. |
【◄】 | Cursor shifts left. |
【►】 | Cursor shifts right. |
【▲】 |
Display the previous option. |
【▼】 |
Display the next option. |
Quick Operation | |
【G/N】 | APL0 Hopper Weighing Mode: Gross Weight / Net Weight display switch. |
APL1 Ration Feeding/Batching Mode: Gross Weight / Net Weight / Feeding Weight display Switch.
|
|
【ZERO】 |
|
【TARE】 |
|
【CAL】 |
|
【▲】【▼】* | * Keep it pressed for 2 seconds: Setpoint parameters setting. |
【PRINT】 | Print Weighing/Batching Report. |
LED Panel-mounting Operation Interface:
Panel-mounting Installation:
Package: