Mini Force Sensor Measurement Indicator
Product Details:
| Place of Origin: | China |
| Brand Name: | Supmeter |
| Certification: | CE |
| Model Number: | BST106-B60S[L] |
Payment & Shipping Terms:
| Minimum Order Quantity: | 5pcs |
|---|---|
| Price: | Negotiation |
| Packaging Details: | carton |
| Delivery Time: | 3work days |
| Payment Terms: | T/T, Western Union |
| Supply Ability: | 10000pcs/month |
|
Detail Information |
|||
| Power Suppu: | DC24V | Max Connect: | 8loadcell[350Ω] |
|---|---|---|---|
| COM1: | RS232 | Outlize Size: | 107*60*100mm |
| Operationg Temperature: | -25℃to45℃ | ||
| Highlight: | weight scale indicator,digital indicator with remote display |
||
Product Description
Weight / Force Display Digital Scale Indicator With Red Led Digital Tubes , Mini Digital Scale Indicator
Main Application:
H16[A]: Single-weighing-hopper/bag Ration Packing Scale
H16[D]: Loss-in-weighing Ration Packing Scale
Main Features:
1:32-bit ARM CPU with 72MHz clock and high arithmetic speed.
2: Auto Zero Tracking
3: Fall Value Auto Correction
4: Target Batch Count & Target Batch Weight Control
5: Auto Pause for Deviation Alarm
6: Auto Re-feed for Negative Deviation Alarm
7: 3-speed[high/medium/low]feeding control by DOs or AOs
8: Definable AO/COM[Communication Port]
Technical Specifications:
| Power Supply | AC24V±20% |
| Display | 5 Red Led Digital Tubes for English&Digit Display |
| Sampling Frequency | 1280Hz |
| A/D Convert | 24-bit |
| Keypad | 4 keys for Shortcut mode operation with key tone |
| Excitation Voltage Output of Loadcell | DC5V |
| Max. Connection number of Loadcell | 8 Loadcells (350Ω) |
| [mV]Signal Input Range | 0-19.5mV |
| DO | 2 Normally Open Transistor Switch Outputs |
| AO | 1Analog Signal Output: 4~20mA. |
| Communication Port | COM1:RS232;COM2:RS485 |
| Outline Dimension | 107 × 60 × 100 mm (W×H×D) |
| Net Weight | Approx. 1.2kg |
| IP Grade | IP65 |
Keypad Operation
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
| Menu Operation | |
| Key Name | Description |
| 【■】 | Enter Main Menu / Exit. |
| 【8】 | Enter / Save / Alarm Acknowledge. |
| 【►】 |
Cursor shifts right. Display the previous option. |
| 【▲】 |
Display the next interface or option. Digit input: +1 ( 0~9 loop). |
|
Quick Operation Mode A Parameter [904]= ‘0. dE’ [Default Set] |
|
| Key Name | Description |
| 【■】* |
|
|
【►】 (【SET】) |
Setpoint parameters setting. |
|
【►】* (【ZERO】) (【→0←】) |
|
|
【▲】* (【TARE】) (【→T←】) |
|
|
【8】 (【G/N】) |
Gross Weight / Net Weight / Net Weight Peak Value display switch. |
|
【8】* (【CLS】) |
|
Weight / Force Display Digital scale indicator with Red Led Digital Tubes , Mini Digital Scale Indicator
![]()
Operation Interface Diagram:![]()
Installation:
![]()
Package:
![]()