• VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm
  • VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm
VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm

Product Details:

Place of Origin: China
Brand Name: Supmeter
Certification: CE
Model Number: BST106-H18

Payment & Shipping Terms:

Minimum Order Quantity: 1pcs
Price: Negotiation
Packaging Details: 1pcs/box
Delivery Time: 3-10 working days
Payment Terms: T/T, Western Union
Supply Ability: 1000pcs/month
Get Best Price Contact Now

Detail Information

Power Supply: AC85-264V DI: 7
DO: 12 COM1: RS232
COM2: Optional RS2332/RS485/Ethernet
High Light:

digital load cell indicator

,

digital display system and indicators

Product Description

VFD Ration Batching Controller Digtal Weight Indicator For 5-Material Ration Batching Scale

 

      Main Features:

  • Suitable for Ration Batching Scale with 5-Material&2-Speed Feeding [Single-Scale Mode].
  • EMC design with high anti-jamming capability, suitable for industrial environment.
  • 32-bit ARM CPU with 72MHz clock & higher arithmetic speed.
  • 6+10 green VFD digital tubes for English character and digit display.
  • 8-key English keypad.
  • Menu&Shortcut mode operation with key tone.
  • 24-bit High-precision and high-speed ∑-△A/D conversion module with 1/1,000,000 internal resolution and sampling frequency 400Hz.
  • Special anti-vibration digital filtering algorithm for ensuring the weighing stability and accuracy when there is strong vibration on the load receptor, and the rapid response capability when the weight signal changes.
  • Max. Connection Quantity: 8 Loadcells (350Ω).
  • Auto Zero Initial Calibration after Power-on, Auto Zero Tracking, Zero Fine Adjustment, Zero Calibration and Load Calibration functions available.
  • Optional Data Calibration function.
  • Auto-locking, Key-locking, Key-unlocking, Digital Setting&Calibration and I/O Testing functions available.
  • 7 Normally open switch inputs [DI] and 12 normally open transistor switch outputs [DO].
  • Optional ‘High/Low Speed Feed’ DOs for feeding control. Optional Low-speed Feeding Modes: Continuous Feeding Mode and Inching Feeding Mode.
  • 1 Optional and definable analog signal AO[4~20mA] for weight signal output or ‘High/Low Speed Feed’ control.Optional ‘Fall Value Auto Correction’ function.
  • 10 Recipes for batching control.
  • Optional ‘Fall Value Auto Correction’ function.
  • Optional ‘Auto Pause for Deviation Alarm’, ‘Auto Pause for Gross Weight Upper Limit Alarm’ and ‘Manual Pause’ functions.
  • Optional ‘Target Batch Control’ function [With Target Batch Count finished, the batching process will stop automatically].
  • ‘Batching Process Power-off Protection’ function available.
  • 2 Optional communication ports for connecting Host IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
  • The present Batch Record can be printed automatically and manually.
  • 500 Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
  • With the multitasking mode, the weighing&control process will not be interrupted by parameter setting and the other operations.

 

    Pictures

 

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm 0

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm 1

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm 2

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm 3

   Technical Specification

  • Executing Standard
  • CMC GB/T 7724-2008PRC National Standard.
  • OMIL R76: 2006International Recommendation.
  • Accuracy Grade: III.
  • Verification Accuracy: 0.02%.
  • Static Weighing Accuracy: 0.2%~0.5%.
  • Batching Accuracy: 0.2%~0.5%.
  • Display
  • 6+10 Green VFD digital tubes for English character and digit display.
  • Weight Display Range: -99,999~+999,999.
  • Scale Capacity: Setting Range 1~999,999.
  • Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.
  • Display Resolution: 1/100,000.
  • Weight Unit: Optional kg, t, g, none.
  • Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.
  • Display Refreshing Time: Setting Range 0.01~1.00s.
  • Kaypad
  • 8-key English keypad.
  • Menu&Shortcut mode operation with key tone.
  • Loadcell Interface
  • Excitation Voltage/Max. Current: DC10V/250mA [8-350Ω loadcells].
  • Signal Input Range: 0~25mV.
  • Output Sensitivity of Loadcell: 1.0~2.5mV/V.
  • 24-bit ∑-△ADC with internal resolution 1/1,000,000.
  • Sampling Frequency: 400Hz.
  • Special anti-vibration digital filtering algorithm.
  • Zero Drift: ±0.1μV/℃ RTI (Relative to Input).
  • Gain Drift: ±5ppm/℃.
  • Non-linearity: 0.005%FS.
  • Switch&Analog Signal Interface
  • 7 Normally Open Switch Inputs [DI].
  • 12 Normally Open Transistor Switch Outputs [DO]: DC24V, 500mA.
  • 1 Optional&Definable Analog Signal Output [AO]: 4~20mA, Non-linearity: 0.05%FS.
  • Digital Communication Interface
  • COM1: RS232.
  • COM2 Optional: RS232/RS485/RS422/Profibus-DP/Ethernet modules.
  • Connectable: Host IPC/PLC, LED Remote Display, Serial Printer and Wireless Module.
  • Report Print
  • The present Batch Record can be printed automatically and manually.
  • 500 Historical Batch Records, Totalizing Reports and Recipes can be queried and printed.
  • Operating Specification
  • Optional Operating Voltage
  • Operating Voltage 1: DC24V±20%.
  • Operating Voltage 2: AC85~264V, 50/60Hz.
  • Operating Voltage 3: AC220V±15%, 50/60Hz.
  • Free to configure one of them.
  • Max. Power Consumption: 10W.
  • Outline Size
  • Model Panel-mounting: 164×82×188mm [W×H×D].
  • Model Explosion-proof: 340×390×205mm [W×H×D].
  • Panel Cut-out Size
  • Model Panel-mounting: 153×77mm [W×H].
  • Operating Temperature: -25℃ to +45℃.
  • Storage Temperature: -30℃ to +60℃.
  • Relative Humidity: Max. 85%RH.
  • Application Environment of Model Explosion-proof
  • Explosion gas environment: Zone 1&2.
  • Classes of explosion gas mixture: IIA, IIB.
  • Temperature grades of explosion gas mixture: T1~T6.
  • Ex-mark: Ex d IIB T6 Gb.
  • Protection Level
  • Front Panel of Model Panel-mounting: IP65.
  • Model Explosion-proof: IP65.
  • Weight
  • Model Panel-mounting: Approx. 1.6kg.
  • Model Explosion-proof: Approx. 19.2kg.

     Model Panel-mounting Operation Interface

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm 4

 

       Keypad Operation

 

If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.

 

Menu Operation
Key Name Description
【MENU】 Enter Main Menu / Exit.
【ENT】 Enter / Save / Alarm Acknowledge.
【◄】 Cursor shifts left.
【►】 Cursor shifts right.
【▲】

Display the previous interface or option.

Digit input: +1.

【▼】

Display the next interface or option.

Digit input: -1.

Quick Operation

【Ñ】

*

  • Key-locking.
  • Key-unlocking.
【SET】 M1~M5 Target Values setting.
【G/N】 Gross Weight / Net Weight display switch.

【→C←】

【CAL】

*

Load Calibration.

【→0←】

【ZERO】

*

  • [-ZEro-]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
  • [≡ZEro≡] Zero Fine Adjustment without Power-down Protection and without Clearing Tare Weight.
  • The controller will switch to Gross Weight display.

【→T←】

【TARE】

*

  • [≡tArE≡]: Manual Tare without Power-down Protection.
  • [-PStr-]: Preset Tare Weight with Power-down Protection.
  • [-rStr-]: Clear Tare Weight with Power-down Protection.
  • The controller will switch to Net Weight display.
【,】* Record Query.
【/】* Clear Screen: Clear the display value of Tatal Feeding Weight, Totalized Weight and Batch Count.
【‡】* Time display and setting.
【±】 ‘+’/‘-’ switch.
【6】

Main Display Interface:

  • [bAt.tAb]: Print Present Batch Record.
  • [tot.tAb]: Print Totalizing Report.
  • [SEt.tAb]: Print Present Recipe.

Record Query state: Print Historical Batch Record.

【ENT】

Pause State:

  • [Cont]: Recover Running.
  • [StoP]: Stop.

*: Keep the key pressed for 2 seconds.

 

       

         State Indication

 

Sign Description
[GROSS] Gross Weight display.
[NET] Net Weight display.
[LOCK]

ON: Key-locked.

OFF: Key-unlocked.

[◣◢] Weight is stable: Weight Variance per [107] ‘Stablity Judging Time’ is in [106] ‘Stablity Judging Range’.
[→0←] The present Gross Weight or Net Weight display value is in ‘Display Value Auto-Zero Range’.
[kg/t/g] Weight unit.
[ NUM] Material No. display.
[ PCS] Batch Count display.
[TOT]

Totalized Weight display.

Total Feeding Weight display.

[SET]

Target Value display.

Parameter setting state.

[RUN]

ON: Running state.

Blinking: Pause state.

OFF: Stop or Calibrating state.

[ZERO] Net Weight ≤ Non-load Zero Range.
[NZ] It’s allowed to do Zero Fine Adjustment.
[SP1] High-speed Feeding.
[SP3] Low-speed Feeding.
[FILL] Stop state: Weight value is increasing.
Running state: It’s in the feeding process.
[COMP]

ON: It’s doing comparation between Feeding Weight and Target Value.

OFF: It turns off in Comparing-prohibited Time.

[DEV] Positive/Negative Deviation Alarm.
[FALL] ON: Fall Value Auto Correction function is open.
[DISC] Stop state: Weight value is reducing.
Running state: It’s in the dumping process.
[HH] Gross Weight Upper Limit Alarm.

 

              Model Panel-mounting Installation

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm 5

          Model AC85~264V/AC220V Terminal

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm 6

        System Diagram for M1~M5 Ration Batching System

VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm 7

 

Want to Know more details about this product
I am interested in VFD Ration Batching Digital Weight Indicator Anti - Vibration Digital Filtering Algorithm could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.